The flow loop: when PI is the answer
Can anything beat a well-tuned PI on a fast, noisy flow loop, and what would it cost?
Step-by-step industrial problems with live simulations and honest engineering verdicts. From flow loops where PI is all you need to high-order multi-variable processes requiring state feedback or MPC.
Can anything beat a well-tuned PI on a fast, noisy flow loop, and what would it cost?
A flow loop cycles day and night, and the first instinct is to detune it. How do you tell a sticky valve from a tuning problem, from the trend alone?
The process gain changes about 7× from bottom to top. What does that do to a PI loop, and which fix is worth it?
On the flow loop derivative only added noise. On a lag-dominant vessel, does D finally pay for itself?
Three upsets reach the outlet temperature by three different paths. Which tool fixes which, and is it worth the extra instruments?
A level loop that holds its setpoint perfectly and is still doing the wrong job. What should a buffer tank's controller actually do?
Thirty seconds of belt between the screw and the scale. How much faster can a controller that predicts the measurement be, and what happens when its prediction is wrong?
More steam makes the level rise. More feedwater makes it fall. How do you control a level that lies to you, and what does each extra measurement buy?
One recycle valve holds the discharge pressure and keeps the compressor out of surge. What does it take to do both, when a user can trip at any moment?
The boiler can only spare 1000 kg/h. How do you control the temperature without ever taking more, and what goes wrong when the limiter isn't built right?
One temperature controller, a steam valve and a cooling water valve. Why does a loop that was fine during start-up start hunting once the reaction is running?
Production sets the diluent flow, and the product must stay at 10 % whatever it does. Feedback, feedforward, or ratio, and why does it matter which?
A load on a rope swings every time the trolley moves. Can a PID put it down quickly and hanging still, and if not, what can?
A shaft between motor and roll rings at 12 Hz. How fast can the roll speed be controlled, and what does it take to go faster?
The plant falls (or jumps) on its own. What does that demand of the controller, and does it need anything beyond PID?
Hot and cold water set both the level and the temperature. Which valve should control what, and is it worth decoupling them, or handing both to an MPC?
An exothermic batch makes the reactor slow and touchy while the reactant lasts and easy afterwards. Does it need adaptive control or ADRC, or a PI tuned for the right stage, and where do controllers stop being the answer?
What is a controller, line by line? Write one in Structured Text, run it on the bench, and see how its edge cases show up in the tests.